Search is Powered by Google
Follow us on:
Follow our health news on Twitter
Follow Our News on Facebook
Personalization
login | register
Radiology / Nuclear Medicine News

First Science From The Compact Light Source: A Miniature Synchrotron For Your Home Lab

Main Category: Radiology / Nuclear Medicine
Also Included In: Medical Devices / Diagnostics;  MRI / PET / Ultrasound;  Biology / Biochemistry
Article Date: 07 Jan 2009 - 5:00 PDT

email icon email to a friend   printer icon printer friendly   write icon view / write opinions   rate icon rate article
Current Article Ratings:

Patient / Public:not yet rated

Health Professional:not yet rated

Article Opinions: 0 posts

In 2004 Lyncean Technologies announced the construction of the Compact Light Source (CLS), a miniature synchrotron which uses inverse Compton scattering to produce high-intensity, tunable, near-monochromatic x-ray beams. The CLS was designed to bring state-of-the-art protein structure determination to the home laboratory - but it has also promised to have a broad impact across the spectrum of x-ray science.

Today, 7th January, at the 39th Winter Colloquium on the Physics of Quantum Electronics, Ronald Ruth, Ph.D., president of Lyncean Technologies, announced that the CLS has started delivering on this promise by achieving three key milestones using its unique x-ray beam: First scientific publication from the CLS featured by the Journal of Synchrotron Radiation on its January 2009 cover; first micro-tomographic images from the CLS; and first protein crystallography data set from the CLS.

The Compact Light Source prototype effort was funded by the National Institute of General Medical Sciences (NIGMS) Small Business Innovation Research (SBIR) program as an advanced technology related to the NIGMS Protein Structure Initiative (PSI). The CLS technology is based on an electron beam stored in a miniature storage ring colliding repeatedly with an opposing infrared light pulse stored in a high-finesse cavity. Each collision produces x-rays through inverse Compton scattering. The entire x-ray source fits in a 10x25 ft room similar in size to those used for Magnetic Resonance Imaging in medical clinics.

The first scientific publication using the CLS x-ray beam employs a technique called Differential Phase Contrast Imaging (DPCI) developed by Professor Franz Pfeiffer and collaborators at the Paul Scherrer Institute in Switzerland. DPCI uses a pair of micron-scale gratings to create two images, one sensitive to the phase of the x-ray wave front and the other sensitive to the local scattering power. This technique has been primarily developed at x-ray beam lines in large synchrotrons, and it relies on a small point-like x-ray source to achieve the coherence necessary for the fringes. The Compact Light Sources has an x-ray beam that is a perfect match for the technique.

Prof. Pfeiffer explained the motivation for imaging with the CLS x-ray beam, "High-resolution, soft-tissue imaging has been pursued at the large synchrotrons for the past 15 years, but to be useful to the biomedical community, the new methods must be able to use x-ray sources that are laboratory or clinical in scale. Differential Phase Contrast Imaging can use the full intensity of the CLS beam and can take advantage of its tiny source size and moderate divergence to image a field of view in the 10 cm range with very small pixel size. This will first open research and development applications such as small animal imaging, the study of tumor growth models or the development of Alzheimer's plaques in brain samples. Clinical applications might extend from mammography to osteoarthritis."

"We are only just beginning to exploit the benefits of the CLS for DPCI," continued Pfeiffer, "The JSR paper shows results from the very first experiments using the CLS for DPCI. Since then, we have also performed the first computed tomography using the CLS x-ray beam, and we are planning our next round of experiments this spring with higher x-ray energy (20 keV), higher intensity, and finer resolution."

In the second round of the Protein Structure Initiative, further CLS development was included in the Accelerated Technology Center for Gene to 3D Structure (ATCG3D, http://www.ATCG3D.org) supported by both NIGMS and the National Center for Research Resources (NCRR). "The focus of the CLS development has been towards protein crystallography," said Professor Ruth, "and with the ATCG3D Beta CLS we had the opportunity to improve performance and reliability. We now have the Beta CLS nearly ready for installation and further development."

"Using many of the ATCG3D CLS subsystems together with the prototype CLS", Ruth continued, "we saw our first protein diffraction in November and on our second crystal, we collected a data set with 3 Å resolution. This was made possible by close collaboration with ATCG3D and in particular with Dr. Michael McCormick of the Peter Kuhn and Ray Stevens laboratory at The Scripps Research Institute. After the ATCG3D Beta CLS is commissioned, we will improve performance to make data collection rapid and routine."

Dr. Lance Stewart, director of ATCG3D and President of deCODE biostructures, commented on the imaging results and the first crystallography at the CLS, "The ATCG3D is very pleased to have had the opportunity to help develop the Compact Light Source. I believe the CLS technology will be important for both soft tissue imaging and protein crystallography."

"With the publication of the first scientific results and the collection of the first set of crystallography data using the CLS, the instrument has demonstrated its potential to have a broad impact on biomedical research," said Jeremy M. Berg, Ph.D., director of NIGMS. "The wide availability of an intense, tunable x-ray tool could transform numerous fields of research by improving access to a key resource."

----------------------------
Article adapted by Medical News Today from original press release.
----------------------------

Lyncean Technologies, Inc. is located in Palo Alto, California. It was founded in 2001 by Stanford Professor Ronald Ruth, Jeffrey Rifkin, M.A. and Rod Loewen, Ph.D. The Compact Light Source concept is based on research performed earlier by Prof. Ruth, Dr. Zhirong Huang and Dr. Rod Loewen at Stanford Linear Accelerator Center and Stanford University. For more information visit http://www.lynceantech.com.

39th Winter Colloquium on the Physics of Quantum Electronics (http://www.pqeconference.com/pqe2009/)

Journal of Synchrotron Radiation January cover (http://journals.iucr.org/s/issues/2009/01/00/issconts.html)

Source: Ronald Ruth
Lyncean Technologies, Inc.

Ad Banner - <1 msv can you beat this? The International CT Image Contest - Call for entries now open.


Personalized Homepage Weekly Newsletters Daily News Alerts
Hemophilia Opioid Induced Constipation Pneumococcal Disease ADHD Anxiety Asthma Atrial Fibrillation Autism Cancer Diabetes Lung Cancer Lupus Medicare / Medicaid Obesity and BMI Pancreatic Cancer Stem Cells All 'What Is...' Articles

Ophthalmology Urology
About Us News Licensing Free Website Feeds Free Tools & Content Tell a Friend Accessibility Help / FAQ Article Submission Links Contact Us

add medical news today to your facebook
medical news gadget

Please fill in our survey

Swine Flu Image

Swine Flu Updates

- Latest Swine Flu News
- What is Swine Flu?
- Map Of H1N1 Outbreaks
- Swine Flu - Top 20 FAQ
- Daily Email News Alerts
Stick with Medical News Today for the latest news updates on swine flu.


These are the most read articles from this news category for the last 6 months:
Top Article Star
Cellphones Cause Brain Tumors, Says New Report By International EMF Collaborative
26 Aug 2009
A new report, "Cellphones and Brain Tumors: 15 Reasons for Concern, Science, Spin and the Truth Behind Interphone," was released today by a collaborative of international EMF activists...


Keeping Bacteria from Cross Contaminating Your Food
Keeping Bacteria from Cross Contaminating Your Food

Raw meat, poultry and seafood can contain harmful bacteria. To keep them from spreading to other food, it's important to keep raw perishables separate from ready to eat foods.

more videos are available in our health videos section.