New Studies Presented At European Society Of Anaesthesia Further Validate Masimo PVI(TM) For Noninvasive And Continuous Fluid Monitoring
Main Category: Pain / AnestheticsAlso Included In: Medical Devices / Diagnostics; Clinical Trials / Drug Trials; Conferences
Article Date: 13 Jun 2009 - 2:00 PDT
Masimo (Nasdaq: MASI), the inventor of Pulse CO-Oximetry(TM) and Measure-Through Motion and Low-Perfusion pulse oximetry, announced that three new independent studies demonstrating the clinical accuracy and utility of Masimo PVI as a noninvasive and continuous measure of patient fluid status and responsiveness were presented this week at the European Society of Anaesthesiology (ESA) Annual Congress in Milan, Italy.
Although fluid administration is critical to optimizing patient status and enabling end organ preservation, unnecessary fluid administration is associated with increased morbidity and mortality. Traditional invasive measurements such as central venous pressure are not reliable to predict whether a patient will benefit from fluid administration, and newer more reliable methods to predict fluid responsiveness are also invasive and costly. Multiple recent studies have shown that Masimo PVI provides a simple and cost-effective method for accurate, noninvasive, and continuous monitoring of fluid responsiveness. The three studies presented at the ESA reinforce the accuracy of PVI compared to invasive measures and highlight its value for before, during, and after anesthesia.
Does the Pleth Variability Index correlate with stroke volume variation? Researchers in the Department of Anesthesiology at the Hamamatsu University School of Medicine in Hamamatsu-City, Japan, compared the accuracy of Masimo PVI measurements with Stroke Volume Variation (SVV) obtained via an invasive catheter (Flo Trac(R)) in 13 patients. After analyzing data recorded at five points--in the supine position, lateral position, start and end of one-lung ventilation, and in the supine position again--researchers found a significant correlation between PVI and SVV (r = 0.75; p = 0.02). The study concluded that "Our results suggest that an accurate prediction of fluid responsiveness can be obtained non-invasively using the PVI."(1)
The Change of Upper Limbs PVI in Spinal Block (Comparison in High Spinal Block and Non-High Spinal Block)
At the Tokai University School of Medicine in Tokyo, Japan, researchers examined how PVI in the upper limbs of patients undergoing caesarean procedures for hernia surgery changed in response to the level of spinal block reached. PVI was recorded in all patients before and every two minutes after spinal block was performed. In patients reaching the anesthetic level C-area--identified as the high spinal block group--PVI decreased. In patients who did not reach the C-area--identified as the non-high spinal block group--PVI of the upper limbs did not change significantly. Researchers summarized that high spinal block dilates vessels and increases blood flow in the upper limbs, which in turn, is shown by decreased PVI.(2)
Perfusion Index and Pleth Variability Index After Administration of General Anesthetic Agents
In this study, anesthesiologists at the Teikyo University School of Medicine in Tokyo, Japan, analyzed changes in PVI and Masimo perfusion index (PI) in 21 surgical patients before and after administration of general anesthetic agents. After administration of general anesthetic agents and 10ml/kg/hr of fluid during induction, PVI significantly decreased from 22.9=/+8.1 to 17.1=/+7.2 (p<0.05) and PI significantly increased from 2.1=/+1.7 to 3.8=/+2.3 (p<0.001), leading researchers to conclude that "an increase in peripheral perfusion and improvement of fluid status and preload" occurred "after administration of general anesthetic agents and intravenous fluid administration during anesthesia induction."(3)
Michael O'Reilly, MD, EVP of Medical Affairs at Masimo, stated; "These studies confirm what previous results have shown--that PVI's accuracy at predicting fluid responsiveness is better than traditional measurements and similar to the newer invasive monitoring techniques at fraction of the cost and complexity. Because PVI is noninvasive and is available from the same sensor used with Masimo Rainbow SET(R) Pulse CO-Oximeters, it has the strong potential to expand and improve fluid monitoring and management in patients who would otherwise not be monitored with the newer invasive techniques."
PVI is available as part of Masimo Rainbow SET Pulse CO-Oximetry(TM)--the first-and-only technology platform to noninvasively measure blood constituents and fluid responsiveness that previously required invasive procedures, including: noninvasive and continuous total hemoglobin (SpHb(TM)), oxygen content (SpOC(TM)), carboxyhemoglobin (SpCO(R)), methemoglobin (SpMet(R)), and PVI, in addition to the 'gold standard' Measure-Through Motion and Low-Perfusion performance of Masimo SET(R) oxyhemoglobin (SpO2), pulse rate (PR), and perfusion index (PI).
1.Y. Kawashima, Y. Shiraishi, S. Sato. Does the Pleth Variability Index correlate with stroke volume variation?. Eur J Anaesthesiol 2009; 26 (Suppl 45): 3AP5-9
2. K. Takeyama, M. Yoshikawa. The change of upper limbs PVI in spinal block (The comparison in high spinal block and non-high spinal block). Eur J Anaesthesiol 2009; 26 (Suppl 45): 3AP5-1
3. J. Mizuno, Y. Morita, A. Kakinuma, S. Morita. Perfusion Index and Pleth Variability Index after administration of general anesthetic agents. Eur J Anaesthesiol 2009; 26 (Suppl 45): 4AP8-3
About Masimo
Masimo (NASDAQ: MASI) develops innovative monitoring technologies that significantly improve patient care--helping solve "unsolvable" problems. In 1995, the company debuted Measure-Through-Motion-and-Low-Perfusion pulse oximetry, known as Masimo SET, which virtually eliminated false alarms and increased pulse oximetry's ability to detect life-threatening events. More than 100 independent and objective studies demonstrate Masimo SET provides the most reliable SpO2 and pulse rate measurements even under the most challenging clinical conditions, including patient motion and low peripheral perfusion. In 2005, Masimo introduced Masimo Rainbow SET Pulse CO-Oximetry, a breakthrough noninvasive blood constituent monitoring platform that can measure many blood constituents that previously required invasive procedures. Masimo Rainbow SET continuously and noninvasively measures total hemoglobin (SpHb(TM)), oxygen content (SpOC(TM)), carboxyhemoglobin (SpCO(R)), methemoglobin (SpMet(R)), and PVI(TM), in addition to oxyhemoglobin (SpO2), pulse rate (PR), and perfusion index (PI), allowing early detection and treatment of potentially life-threatening conditions. Founded in 1989, Masimo has the mission of "Improving Patient Outcomes and Reducing Cost of Care by Taking Noninvasive Monitoring to New Sites and Applications."
Masimo, SET, Signal Extraction Technology, Improving Outcomes and Reducing Cost of Care by Taking Noninvasive Monitoring to New Sites and Applications, Rainbow, SpHb, SpOC, SpCO, SpMet, PVI, Radical-7, Rad-87, Rad-57, Rad-9, Rad-8, Rad-5,Pulse CO-Oximetry and Pulse CO-Oximeter are trademarks or registered trademarks of Masimo Corporation.
Source: Masimo
|
Please rate this article: (Hover over the stars then click to rate) |
Patient / Public: |
or |
Health Professional: |
Any medical information published on this website is not intended as a substitute for informed medical advice and you should not take any action before consulting with a health care professional. For more information, please read our terms and conditions.
Contact Our News Editors
For any corrections of factual information, or to contact the editors please use our feedback form.
![]()
Please send any medical news or health news press releases to:
| Back to top | Back to front page | List of All Medical Articles |
| Privacy Policy | Terms and Conditions | © 2009 MediLexicon International Ltd |