Search is Powered by Google
Follow us on:
Follow our health news on Twitter
Follow Our News on Facebook
Personalization
login | register
Water - Air Quality / Agriculture News

Keeping Safe In Emergencies By Giving Your Power Generator Some Space

Main Category: Water - Air Quality / Agriculture
Also Included In: Public Health;  IT / Internet / E-mail
Article Date: 07 Oct 2009 - 5:00 PDT

email icon email to a friend   printer icon printer friendly   write icon view / write opinions   rate icon rate article
Current Article Ratings:

Patient / Public:not yet rated

Health Professional:5 stars

5 (2 votes)

Article Opinions: 0 posts

To subdue the steaming heat of hurricanes or to thaw out during a blizzard, gasoline-powered, portable generators are a lifeline during weather emergencies when homes are cut off without electricity. But these generators emit poisonous carbon monoxide - a single generator can produce a hundred times more of the colorless, odorless gas than a modern car's exhaust. New research from the National Institute of Standards and Technology (NIST) shows that to prevent potentially dangerous levels of carbon monoxide, users may need to keep generators farther from the house than previously believed - perhaps as much as 25 feet.

Up to half of the incidents of non-fatal carbon monoxide (CO) poisoning reported in the 2004 and 2005 hurricane seasons involved generators run within 7 feet of the home, according to the U.S. Centers for Disease Control and Prevention (CDC).

Carbon monoxide can enter a house through a number of airflow paths, such as a door or window left open to accommodate the extension cord that brings power from the generator into the house. While some guidance recommends 10 feet from open windows as a safe operating distance, NIST researcher Steven Emmerich says the "safe" operating distance depends on the house, the weather conditions and the unit. A generator's carbon monoxide output is usually higher than an automobile's, he says, because most generators do not have the sophisticated emission controls that cars do.

"People need to be aware that generators are potentially deadly and they need to educate themselves on proper use," Emmerich says. With funding from CDC, NIST researchers are gathering reliable data to support future CDC guidance.

NIST building researchers simulated multiple scenarios of a portable generator operating outside of a one-story house, using both a test structure and two different computer models - the NIST-developed CONTAM indoor air quality model and a computational fluid dynamics model.

The simulations included factors that could be controlled by humans, such as generator location, exhaust direction and window-opening size, and environmental factors such as wind, temperature and house dimensions. In the simulations the generator was placed at various distances from the house and tested under different weather conditions.

"We found that for the house modeled in this study," researcher Leon Wang says, "a generator position 15 feet away from open windows was not far enough to prevent carbon monoxide entry into the house."

Winds perpendicular to the open window resulted in more carbon monoxide entry than winds at an angle, and lower wind speeds generally allowed more carbon monoxide in the house. "Slow, stagnant wind seems to be the worst case because it leads to the carbon monoxide lingering by the windows," Wang explains. Researchers determined that placing the generator outside of the airflow recirculation regions near the open windows reduced carbon monoxide entry.

In the next phase of the study NIST will model a two-story house that researchers believe will interact with the wind differently. NIST researchers also have worked with the Consumer Product Safety Commission on related work. (See: "NIST to Study Hazards of Portable Gasoline-Powered Generators," NIST Tech Beat, March 5, 2008.)

The generator study can be downloaded at http://fire.nist.gov/bfrlpubs/build09/PDF/b09009.pdf.

* L. Wang and S.J. Emmerich. Modeling the Effects of Outdoor Gasoline Powered Generator Use on Indoor Carbon Monoxide Exposures. (NIST Technical Note 1637,) 2009.

Source:
Evelyn Brown
National Institute of Standards and Technology (NIST)




Personalized Homepage Weekly Newsletters Daily News Alerts
Hemophilia Opioid Induced Constipation Pneumococcal Disease ADHD Anxiety Asthma Atrial Fibrillation Autism Cancer Diabetes Lung Cancer Lupus Medicare / Medicaid Obesity and BMI Pancreatic Cancer Stem Cells All 'What Is...' Articles

Ophthalmology Urology
About Us News Licensing Free Website Feeds Free Tools & Content Tell a Friend Accessibility Help / FAQ Article Submission Links Contact Us

add medical news today to your facebook
medical news gadget

Please fill in our survey

Swine Flu Image

Swine Flu Updates

- Latest Swine Flu News
- What is Swine Flu?
- Map Of H1N1 Outbreaks
- Swine Flu - Top 20 FAQ
- Daily Email News Alerts
Stick with Medical News Today for the latest news updates on swine flu.


These are the most read articles from this news category for the last 6 months:
Top Article Star
BPA Chemical Leaches From Hard Plastic Drinking Bottles Into The Body, Study
22 May 2009
New research from the US suggests that people who drink from bottles made of polycarbonate plastic, such as that used to make hard-plastic drinking bottles and baby bottles, have a considerably higher level of the chemical...


Keeping Seniors Safe in the Heat
Keeping Seniors Safe in the Heat

Keeping cool this summer means avoiding heat stroke, the most serious heat-related illness, and heat exhaustion, a milder affliction but still a dangerous one. Older people are especially vulnerable to both.

more videos are available in our health videos section.