Detecting deadly fumes in subways, toxic gases in chemical spills, and hidden explosives in baggage is becoming easier and more efficient with a measurement technique called surface-enhanced Raman scattering. To further improve the technique's sensitivity, scientists must design better scattering surfaces, and more effective ways of evaluating them.

Researchers at the University of Illinois, led by chemistry professor Dana Dlott, have devised a method to evaluate substrate surfaces by using a series of killer laser pulses. They describe the method and report measurements for a commonly used substrate in the July 18 issue of the journal Science.

Surface-enhanced Raman scattering, which functions by adsorbing molecules of interest onto rough metal surfaces, typically enhances the Raman spectrum a million times. Hot spots can occur, however, where the electric field enhancement can be a billion or more.

Current surface characterization techniques cannot tell hot spots from cold spots, and create an average value across the entire substrate surface.

"Looking at a spectrum, you can't tell if it's the result of a small number of molecules in hot spots or a large number of molecules in cold spots," Dlott said. "Two materials could have the same average spectrum, but behave quite differently."

Dlott, graduate student Ying Fang and postdoctoral research associate Nak-Hyun Seong came up with a way to measure the distribution of site enhancements on the substrate surface. Using killer laser pulses, their technique can count how many molecules are sitting in the hottest spots, how many are sitting in the coldest spots, and how many are sitting between the two extremes.

The killer pulse is a short duration laser pulse with a variable electric field. When the electric field is strong enough, it rips a molecule apart, "killing" it.

"If a molecule is in a very hot spot on the substrate, where the electric field enhancement is really big, it takes only a weak pulse to kill it," Dlott said. "If the molecule is in a very cold spot, then it takes a really big laser pulse to kill it."

Dlott, Fang and Seong demonstrated their technique by measuring the distribution of local enhancements for benzenethiolate molecules on a substrate of silver-coated nanospheres 330 nanometers in diameter.

To characterize the surface, the researchers first measured the initial Raman intensity. Then they put in a weak killer pulse, which destroyed the molecules in the hottest spots. After measuring the new Raman intensity, they put in a bigger pulse and destroyed the molecules in slightly colder spots. The researchers continued with bigger and bigger pulses until all the benzenethiolate molecules were destroyed.

"We found the hottest spots comprised just 63 molecules per million, but contributed 24 percent of the overall Raman intensity," Dlott said. "We also found the coldest spots contained 61 percent of the molecules, but contributed only 4 percent of the overall intensity."

Measurements like these, of the distribution of local site enhancements, will help researchers design better scattering surfaces for sensor applications.

Prior to this work, no one knew if the Raman intensity was dominated by a small number of hot molecules or a large number of cold ones. Dlott, Fang and Seong have answered that important scientific question; not just with a yes or no, but with a full determination of exactly how many molecules there are in each level of hot or cold.

"Now, when evaluating a new surface-enhanced Raman material, instead of knowing just the average intensity, we know the highest, the lowest, and everything in between," Dlott said.

###

Funding was provided by the National Science Foundation, the Air Force Office of Scientific Research, and the Army Research Office. Electron microscopy was carried out in the university's Center for Microanalysis of Materials, which is supported by the U.S. Department of Energy.

Source: James E. Kloeppel
University of Illinois at Urbana-Champaign

Article adapted by Medical News Today from original press release.
Visit our public health section for the latest news on this subject.
There are no references listed for this article.
Please use one of the following formats to cite this article in your essay, paper or report:

MLA
James E. Kloeppel. "Improving Toxicity Detection." Medical News Today. MediLexicon, Intl., 30 Jul. 2008. Web.
15 Feb. 2012. <http://www.medicalnewstoday.com/releases/116621.php>

APA
James E. Kloeppel. (2008, July 30). "Improving Toxicity Detection." Medical News Today. Retrieved from
http://www.medicalnewstoday.com/releases/116621.php.

Please note: If no author information is provided, the source is cited instead.


Public Health

Tips For Healthy Flying

There was a time when jumping on a plane was a relatively easy thing to do (assuming you had the money). But today's flying experience is often more of an ordeal than a pleasure. Read more...

Do You Know What Drowning Looks Like?

If you and your family are planning to spend some of the summer by the sea, by the pool, or perhaps even a river or lake, perhaps you should ask yourself: do you really know what drowning looks like? Read more...

Most Popular Articles



Follow Our Public Health News On Twitter

Follow Us On Twitter
Get the latest news for this category delivered straight to your Twitter account. Simply visit our Public Health Twitter account and select the 'follow' option.



View list of all 'What Is...' articles »