New Generation Drug-Eluting Stent Demonstrates Equivalent Efficacy To Market Leader In 'Real World' Study
Main Category: Cardiovascular / CardiologyAlso Included In: Clinical Trials / Drug Trials
Article Date: 02 Sep 2008 - 2:00 PDT
| Patient / Public: | ![]() |
2 (1 votes) |
| Healthcare Prof: | ![]() |
3 (1 votes) |
The LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) Study randomly assigned 1,707 patients with 2,472 lesions to treatment with either a biolimus-eluting stent with a biodegradable polymer or a sirolimus-eluting stent with a durable polymer. The study involved a broad range of patients for whom a stenting procedure was considered suitable, designed to reflect routine clinical practice.
Nine months after the procedure, the numbers of deaths, heart attacks and repeat interventions required because of renewed blood vessel narrowing were equivalent in both treatment groups (9.2% of patients in the biolimus-eluting stent group and 10.5% of patients in the sirolimus-eluting stent group). In the one in four patients given an angiogram, the degree of blood vessel narrowing at the site of stent implantation was also equivalent in both treatment groups.
The DES is designed to treat narrowing of coronary arteries which is one of the principal causes of coronary artery disease. Once implanted, it uses the strength of its cylindrical mesh wall to keep the artery widened and maintain blood flow, and gradually releases its drug into the surrounding tissues. The role of the drug is to inhibit restenosis, a common problem following stent implantation, whereby excessive tissue forms around the stent and may negate the benefit that it provides. First-generation drug-eluting stents released the drug from a durable polymer, which may be associated with the formation of blood clots (thrombosis) more than a year after implantation. A new generation of DES has therefore been developed, using a polymer which is completely degraded into carbon dioxide and water after 6-9 months leaving only the metal mesh behind, more closely resembling a bare metal stent.
"The results from LEADERS are significant, as they demonstrate for the first time that a drug-eluting stent with a biodegradable polymer is just as safe and effective as a conventional drug-eluting stent with a durable polymer, under conditions which resemble those of routine clinical practice", commented LEADERS Principle Investigator Professor Stephan Windecker, University Hospital, Bern, Switzerland. "The next stage will be to investigate whether a biodegradable polymer leads to a lower risk of stent thrombosis in the longer term".
EUROPEAN SOCIETY OF CARDIOLOGY (ESC)
The European Heart House
2035 Route des Colles
B.P. 179 - Les Templiers
FR-06903 Sophia Antipolis
http://www.escardio.org
Visit our cardiovascular / cardiology section for the latest news on this subject.
MLA
14 Feb. 2012. <http://www.medicalnewstoday.com/releases/119936.php>
APA
http://www.medicalnewstoday.com/releases/119936.php.
Please note: If no author information is provided, the source is cited instead.
|
Rate this article: (Hover over the stars then click to rate) |
Patient / Public: |
or |
Health Professional: |
Add Your Opinion
Please note that we publish your name, but we do not publish your email address. It is only used to let you know when your message is published. We do not use it for any other purpose. Please see our privacy policy for more information.
If you write about specific medications or operations, please do not name health care professionals by name.
All opinions are moderated before being included (to stop spam)
Contact Our News Editors
For any corrections of factual information, or to contact the editors please use our feedback form.
![]()
Please send any medical news or health news press releases to:
Note: Any medical information published on this website is not intended as a substitute for informed medical advice and you should not take any action before consulting with a health care professional. For more information, please read our terms and conditions.