Abbott's XIENCE V(R) Approved In Japan - Second Largest Drug Eluting Stent Market Worldwide
Main Category: Cardiovascular / CardiologyAlso Included In: Regulatory Affairs / Drug Approvals; Heart Disease
Article Date: 10 Jan 2010 - 0:00 PST
| Patient / Public: | ![]() | |
| Healthcare Prof: | ![]() |
Abbott announced that the Japanese Ministry of Health, Labor and Welfare (MHLW) has approved its XIENCE V® Everolimus Eluting Coronary Stent System for the treatment of coronary artery disease. Japan is the second largest drug eluting stent market in the world after the United States, with approximately 200,000 stent procedures performed each year. The company plans to launch XIENCE V in Japan in the upcoming weeks, immediately following final reimbursement authorization.
"With today's approval, physicians in Japan will now have access to a next-generation drug eluting stent that offers outstanding ease of use and excellent clinical performance and safety. XIENCE V is the ideal combination as documented by the more than 16,000 patients who have been enrolled in the SPIRIT family of trials," said Robert Hance, senior vice president, vascular, Abbott. "Each aspect of XIENCE V's design, from the thin struts to the flexible delivery system to the drug and polymer, was carefully engineered for optimal deliverability and to improve safety and efficacy outcomes for patients compared to earlier generation stents. These attributes have made XIENCE V the market-leading drug eluting stent around the world, and we look forward to making XIENCE V available to physicians in Japan shortly."
"XIENCE V is flexible and easy to deliver through the coronary anatomy to the lesion site. These attributes combined with the strength of the safety and efficacy data supporting it give me confidence that XIENCE V is a true next-generation stent that has the potential to benefit heart patients in Japan," said Shigeru Saito, M.D., F.A.C.C., F.S.C.A.I., F.J.C.C., director, Cardiology and Catheterization Laboratories, Shonan Kamakura General Hospital, and principal investigator for the SPIRIT III Japan Registry.
The outstanding data for XIENCE V includes clinically superior long-term efficacy and safety results in the primary endpoints of the pivotal trials, and among the SPIRIT family of trials. The SPIRIT III Japan Registry of 88 patients demonstrated similar angiographic and clinical results to the outstanding outcomes from the SPIRIT III U.S. trial. In the SPIRIT III Japan Registry, XIENCE V demonstrated a single-digit rate of major adverse cardiac events (MACE, 8.0 percent), and no cases of stent thrombosis (blood clots) out to one year. MACE is an important composite clinical measure of safety and efficacy outcomes for patients and is defined as cardiac death, heart attack (all myocardial infarction or MI), or ischemia-driven target lesion revascularization (ID-TLR).
In the SPIRIT III U.S. trial, XIENCE V demonstrated an impressive low rate of very late stent thrombosis with no additional events between two and three years, and a 43 percent reduction in the risk of MACE compared to the TAXUS® Express2 Paclitaxel-Eluting Coronary Stent System (TAXUS)at three years (9.1 percent for XIENCE V vs. 15.7 percent for TAXUS, p-value=0.003).
Additionally, in the investigator-initiated COMPARE trial of real-world patients, XIENCE V demonstrated significantly better outcomes in key safety and efficacy measures compared to the TAXUS® Liberte Paclitaxel-Eluting Coronary Stent System (TAXUS). At one year, XIENCE V demonstrated a statistically significant 31 percent reduction in MACE compared to TAXUS (6.2 percent XIENCE V vs. 9.1 percent TAXUS, p-value=0.023),2 and a statistically significant 74 percent reduction in stent thrombosis compared to TAXUS (0.7 percent XIENCE V vs. 2.6 percent TAXUS, p-value=0.002)2.In the COMPARE trial, MACE is defined as all death, non-fatal MI and target vessel revascularization.
More About XIENCE V
Abbott's market-leading XIENCE V is used to treat coronary artery disease by propping open a narrowed or blocked artery and releasing the drug, everolimus, in a controlled manner to prevent the artery from becoming blocked again following a stent procedure.
XIENCE V is built upon Abbott's market-leading bare metal stent, the MULTI-LINK VISION® Coronary Stent System. The VISION platform is designed to facilitate ease of delivery, making it easier for physicians to maneuver the stent and treat the diseased portion of the artery.
In some geographies, Abbott supplies a private-label version of XIENCE V to Boston Scientific called the PROMUS® Everolimus-Eluting Coronary Stent System. PROMUS is designed and manufactured by Abbott and supplied to Boston Scientific as part of a distribution agreement between the two companies.
Everolimus, developed by Novartis Pharma AG, is a proliferation signal inhibitor, or mTOR inhibitor, licensed to Abbott by Novartis for use on its drug eluting stents. Everolimus has been shown to inhibit in-stent neointimal growth in the coronary vessels following stent implantation, due to its antiproliferative properties.
XIENCE V is indicated for improving coronary luminal diameter in patients with symptomatic heart disease due to de novo native coronary artery lesions (lesions less than or equal to 28 mm). Additional information about XIENCE V, including important safety information, is available online in Japanese at http://www.xiencev.jp, and in English at http://www.xiencev.com or here.
About Abbott Vascular
Abbott Vascular is a global leader in cardiac and vascular care with market-leading products and an industry-leading pipeline. Abbott Vascular offers a comprehensive cardiac and vascular devices portfolio, including products for coronary artery disease, vessel closure, endovascular disease, and structural heart disease.
About Abbott
Abbott (NYSE: ABT) is a global, broad-based health care company devoted to the discovery, development, manufacture and marketing of pharmaceuticals and medical products, including nutritionals, devices and diagnostics. The company employs more than 72,000 people and markets its products in more than 130 countries.
1 Event rates are based on Kaplan-Meier estimates; p-values based on log-rank test.
2 Event rates are based on Kaplan-Meier estimates.
Source
Abbott
Visit our cardiovascular / cardiology section for the latest news on this subject.
MLA
12 Feb. 2012. <http://www.medicalnewstoday.com/releases/175501.php>
APA
http://www.medicalnewstoday.com/releases/175501.php.
Please note: If no author information is provided, the source is cited instead.
|
Rate this article: (Hover over the stars then click to rate) |
Patient / Public: |
or |
Health Professional: |
Add Your Opinion
Please note that we publish your name, but we do not publish your email address. It is only used to let you know when your message is published. We do not use it for any other purpose. Please see our privacy policy for more information.
If you write about specific medications or operations, please do not name health care professionals by name.
All opinions are moderated before being included (to stop spam)
Contact Our News Editors
For any corrections of factual information, or to contact the editors please use our feedback form.
![]()
Please send any medical news or health news press releases to:
Note: Any medical information published on this website is not intended as a substitute for informed medical advice and you should not take any action before consulting with a health care professional. For more information, please read our terms and conditions.