Ultrasound Measurement Of Fetal Adrenal Gland A Better Predictor Of Preterm Birth

Main Category: Pregnancy / Obstetrics
Also Included In: MRI / PET / Ultrasound
Article Date: 05 Feb 2010 - 0:00 PDT

email icon email to a friend   printer icon printer friendly   write icon opinions  


Current Article Ratings:

Patient / Public:3 stars

3 (2 votes)

Healthcare Prof:4 stars

3.9 (10 votes)

Article Opinions: 1 posts

In a study presented at the Society for Maternal-Fetal Medicine's (SMFM) annual meeting, The Pregnancy Meeting™ in Chicago, researchers unveiled findings that show that measuring the fetal zone of the adrenal gland is a better predictor of pre-term birth than measuring cervical length.

Researchers with the University of Maryland and Yale University have followed up on early research that they conducted using 3D ultrasound methods.

"We previously discovered that 3D adrenal gland volume (AGV) is a very accurate predictor of preterm birth," said Dr. Ozhan Turan, the study's author. "However most people around the world don't have access to that technology, therefore, we have created measurements that can be done with 2D ultrasound that are very effective to predict pre-term birth."

In the study, patients presenting with preterm labor symptoms had ultrasound measurement of the cervical length (CL) and fetal adrenal gland dimension. Using 3D ultrasound with VOCAL cAGV (AGV/ Estimated fetal weight), 2D depth of the whole-gland (D) and fetal zone (d) were measured. The d/D ratio was calculated as an index of FZE. The cAGV, d/D and CL were compared for prediction of preterm birth within seven days.

Sixty-two singletons with preterm labor at 23-37 wks´ gestation were studied. Measurement-to-delivery interval only correlated with cAGV and d/D (r=-0.32 p=0.011 and r=-0.47 p=0.001respectively) but not CL (p=0.83). Twenty women had preterm birth at less than seven days (Group A) while 42 (Group B) delivered in seven days or more from initial assessment. While CL was similar (p=0.5) cAGV and d/D were higher in group A (p< 0.0001 for both). ROC area under the curve was significantly greater for cAGV and d/D than for CL (0.82, 0.91 and 0.59, p< 0.01 and 0.001 respectively, fig) without any significant differences between adrenal gland measurements. Using ROC derived cutoffs for preterm birth in less than seven days was best predicted by d/D and cAGV but not CL.

"Prior to this we haven't had a good method to predict who will present with pre-term labor." said Dr. Turan. "Measuring the cervical length leads to a high percentage of false positives and also it has limited sensitivity," he continued. "Hopefully, if adopted, this method will allow for an easy inexpensive way to identify real pre-term deliveries. Therefore we will be better managing these pregnancies."

Source:
Vicki Bendure
Society for Maternal-Fetal Medicine

Article adapted by Medical News Today from original press release.
Visit our pregnancy / obstetrics section for the latest news on this subject.
There are no references listed for this article.
Please use one of the following formats to cite this article in your essay, paper or report:

MLA
Vicki Bendure. "Ultrasound Measurement Of Fetal Adrenal Gland A Better Predictor Of Preterm Birth." Medical News Today. MediLexicon, Intl., 5 Feb. 2010. Web.
15 Feb. 2012. <http://www.medicalnewstoday.com/releases/178205.php>

APA
Vicki Bendure. (2010, February 5). "Ultrasound Measurement Of Fetal Adrenal Gland A Better Predictor Of Preterm Birth." Medical News Today. Retrieved from
http://www.medicalnewstoday.com/releases/178205.php.

Please note: If no author information is provided, the source is cited instead.




Pregnancy / Obstetrics

Most Popular Articles



Follow Our Pregnancy News On Twitter

Follow Us On Twitter
Get the latest news for this category delivered straight to your Twitter account. Simply visit our Pregnancy / Obstetrics Twitter account and select the 'follow' option.



View list of all 'What Is...' articles »